Wholesale Reusable Lancing Devices

Wholesale Lancing Devices for Pharmacies, Clinics & Distributors

Source reusable pen-style lancing devices for blood glucose testing, capillary blood sampling and recurring diabetes care supply programs.

Compare the Purple ELD-1 and White models by model-specific depth control, activation design, compatible disposable lancets, packaging, documentation and fulfillment requirements.

Adjustable Depth Control Device + Lancet Match SKU-Level Documents Wholesale Packaging
Purple and white Tonmit reusable lancing devices for blood glucose testing supply

Lancing Device Models

Compare Purple ELD-1 & White Lancing Devices

Both models are reusable pen-style devices with adjustable depth control. Purple ELD-1 provides five penetration-depth settings. The White model provides six settings from 0.50 mm to 1.80 mm and uses a different loading / activation architecture.

Purple ELD-1 reusable lancing device for blood glucose testing
Purple Model · ELD-1

Purple ELD-1 Lancing Device

Reusable ELD-1 device with five penetration-depth settings, vacuum-assisted contact-head design, dual-track depth guidance and top-button activation.

REF
ELD-1
Inside Code
ELD-2.0
Depth Control
5 Settings
Device Pack
1 pc / Box · 20 pcs / Case
Vacuum-Assisted Head Top Activation Button BL-30G / BL-30E Compatible
View Purple Model
White reusable lancing device with six adjustable puncture-depth settings
White Model

White Lancing Device

Reusable device with six adjustable puncture-depth settings from 0.50 mm to 1.80 mm, a visible red loading / release indicator, a large activation button and a triple-tunnel internal design that reduces spring vibration.

Device Format
Reusable Pen-Style
Depth Control
6 Settings · 0.50–1.80 mm
Activation
Large Activation Button
REF / Pack
RFQ Confirmation
Red Status Indicator Triple-Tunnel Design Single-Patient Reuse
View White Model

Procurement Controls

Lock the Device + Lancet Configuration Before Quotation

Device depth and activation belong to the reusable lancing device. Gauge, needle dimensions and sterilization belong to the compatible disposable blood lancet. Keep both references aligned in the RFQ.

Device Model & Depth

Confirm the device model and its matching depth configuration — five settings for Purple ELD-1 or six settings for the White model — together with activation design and exact device reference.

Model / REF Model-Specific Depth

Compatible Disposable Lancet

Confirm lancet REF, gauge, diameter, needle length, loading format, sterilization method and packaging as a separate disposable component.

Gauge & REF Sterilization

REF, UDI, IFU & Labeling

Review the exact product identifier, IFU, compatible-lancet information, packaging artwork, labeling and applicable quality or regulatory records by SKU.

REF / UDI IFU & Labeling

Packaging, Stock & Lead Time

Confirm device and lancet pack hierarchy, MOQ or sample requirement, current U.S. stock status, destination and lead time for the selected supply route.

MOQ / Sample Stock / Lead Time

Lancing Device Supply Review

Send the Device + Lancet Requirement

Include the device model, compatible lancet, estimated quantity, destination and any packaging, labeling or documentation requirements.

  • Purple ELD-1 or White device
  • Compatible lancet REF / gauge
  • Device and lancet quantities
  • Shipping destination and timing
  • Private label and document requirements
Inquiry type Lancing Device Supply Review
Tonmit B2B Product Inquiry

By submitting this form, you acknowledge that you have read our Privacy Policy .

Product Evaluation

Model-Specific Lancing Device Features

Evaluate model-specific depth control, compatible lancet requirements, reusable single-patient use and loading or activation features before standardizing a device SKU.

Adjustable depth controls for Purple and White reusable lancing device models
Depth Control

Model-Specific Depth Adjustment

Purple ELD-1 provides five penetration-depth settings. The White model provides six settings: 0.50, 0.76, 1.02, 1.28, 1.54 and 1.80 mm. Depth is a device setting and should not be confused with lancet gauge.

Purple: 5 Settings White: 6 Settings
Reusable lancing device displayed with a compatible disposable blood lancet
Compatibility

Compatible Lancet Requirements

Gauge alone does not establish compatibility. Confirm the lancet REF, shaft and loading format, dimensions and current device compatibility before approving a substitute.

REF + Gauge Loading Format
Reusable pen-style lancing devices with replaceable disposable lancets
Use Conditions

Reusable Single-Patient Device

The lancing-device body is reusable for one patient according to the applicable label and IFU, while the compatible blood lancet is a separate disposable component.

Single-Patient Use IFU Controlled
Lancing device loading, activation, cap removal and lancet removal steps
Operating Design

Model-Specific Loading & Activation

Purple ELD-1 uses a top activation button and vacuum-assisted contact head. The White model uses a large firing button, visible red loading / release indicator and triple-tunnel spring-guidance design.

Purple Top Button White Triple-Tunnel Design
Device / lancet distinction: depth control and activation are reusable-device specifications. Gauge, needle dimensions and sterilization belong to the matched disposable lancet. Safety-lancet retraction or anti-reuse features, when required, should be evaluated separately from this reusable-device category.

Buyer Decision Matrix

Lancing Device Specifications for B2B Ordering

Use confirmed model data where available and keep unpublished identifiers, packaging, inventory and lead-time fields under exact-SKU or RFQ control.

2 Reusable Device Models Adjustable Depth Control Device + Lancet Match SKU-Level Documents
Comparison of Purple ELD-1 and White reusable lancing devices for B2B purchasing.
Buyer Field Purple ELD-1 White Device
Device Format Reusable pen-style device Reusable pen-style device
REF / Product Code ELD-1 · Inside Code ELD-2.0 Exact REF / product code confirmed on quotation
Depth Control 5 penetration-depth levels 6 adjustable settings · 0.50 / 0.76 / 1.02 / 1.28 / 1.54 / 1.80 mm
Activation Top-button activation Large activation button
Model-Specific Design Vacuum-assisted contact head · dual-track depth guidance Red loading / release indicator · triple-tunnel spring-guidance design
Compatible Lancet BL-30G / BL-30E entry; selected square-shaft lancets Compatible disposable blood lancet confirmed by device configuration
Lancet Gauge / Sterilization BL-30G: 30G · Ø0.30 mm · 3 mm · Gamma irradiation Defined by the matched disposable lancet, not the reusable device
Device Packaging 1 pc / Box · 20 pcs / Case RFQ confirmation
Lancet Packaging BL-30G: 100 pcs / Box · 10,000 pcs / Case Defined by the selected compatible lancet REF
MOQ / Sample RFQ confirmation RFQ confirmation
U.S. Inventory Written stock confirmation Written stock confirmation
Lead Time Confirmed by quantity, supply route and destination Confirmed by quantity, supply route and destination
REF / UDI / IFU / Documents Published REF; UDI and document set reviewed by exact SKU Exact product identifier and document set reviewed by SKU

Supply Program Review

Packaging, Labeling & Documentation

Device + Lancet Pack Hierarchy Private Label Packaging Artwork & Labeling REF / UDI / IFU Review U.S. Inventory Review Lead Time Confirmation
Ordering note: Purple ELD-1 / ELD-2.0 data and its current device pack are published. The White model has six confirmed puncture-depth settings from 0.50 mm to 1.80 mm; its exact REF, pack hierarchy, UDI, MOQ, current inventory and lead time remain controlled by the quoted SKU and supply route.

Lancing Device Supply Review

Confirm the Device, Lancet & Pack Hierarchy Before Ordering

Send the selected device model, compatible lancet, quantity, destination, packaging, labeling and documentation requirements for an exact-SKU quotation review.