STAINLESS-STEEL COOLING CUP PRODUCT FAMILY

Wholesale Insulin Cooling Cups by Model

Compare stainless-steel cooling cup systems with cold-gel bottle inserts by internal clearance, medication fit, included components and model-specific performance evidence. Final configuration, preparation, packaging and document scope must match the exact quoted model.

  • Stainless-steel insulated cup format
  • Cold-gel bottle insert configuration
  • Pen, cartridge or vial fit confirmed by model
  • Internal test evidence tied to the tested configuration
Blue stainless steel insulin cooling cup with cold-gel bottle and carrying accessories
Representative cold-gel-bottle system. Confirm the cup dimensions, insert preparation, medication fit and included components against the selected model.
PRODUCT FORMAT Stainless-steel insulated cup

Construction and dimensions confirmed by model

COOLING INSERT Cold-gel bottle insert

Model, quantity and preparation confirmed before use

INTERNAL TEST CONDITIONS 30°C · 35°C · 40°C ambient

Separate Tonmit internal test conditions

PERFORMANCE BASIS Configuration-specific

Cup, insert, load and test conditions must match

PRODUCT-SPECIFIC DIFFERENCES

Review the Complete Cup-and-Insert System

The cup body alone does not define fit or cooling performance. Confirm these four model-level controls before approving a purchase.

Blue stainless steel insulin cooling cup showing the metal opening and insulated body
01 / CUP BODY

Stainless-Steel Cup Format

Confirm external dimensions, usable internal clearance, insulation construction, cap or closure, finish and carrying accessories.

Cold-gel bottle configurations for a blue stainless steel insulin cooling cup
02 / COOLING INSERT

Cold-Gel Bottle Configuration

Confirm the supplied bottle model, quantity, dimensions, preconditioning time, placement and preparation instructions.

Insulin cooling cup with a cold-gel bottle inserted into the stainless steel body
03 / MEDICATION FIT

Internal Clearance by Model

Match the intended pen, cartridge or vial format to the usable internal diameter and height with the cooling insert installed.

Insulin cooling cup supply set with cooling bottles, packaging boxes, drawstring bags and instructions
04 / SUPPLIED SET

Packaging & Included Components

Confirm the cup, inserts, pouch, instructions, label version, unit packaging and carton configuration on the quotation.

SKU-LEVEL PROCUREMENT CONTROL

Fields to Lock Before Approving a Cooling Cup

Product images represent the family. Final dimensions, components, performance, packaging and commercial terms should reference the exact model or item code used on the quotation.

Control Field Product-Family Information Required Written Confirmation
Model / item code Insulin cooling cup product family Exact model or SKU on the quotation and all applicable files
Cup construction Rigid stainless-steel insulated format Materials, external dimensions, internal clearance, closure and finish
Cooling insert Cold-gel bottle configuration Bottle model, quantity, dimensions, preconditioning, position and included status
Medication fit Selected pens, cartridges or vials subject to internal clearance Intended container, usable internal diameter and height with the insert installed
Cooling performance Internal duration summary available for 30°C, 35°C and 40°C ambient test conditions Tested cup-and-bottle model, report ID / revision, preparation, load, sensor position, test conditions and acceptance criteria
Packaging Pouch, instructions and retail or bulk pack vary by SKU Included components, unit pack, carton quantity, dimensions and label version
Commercial basis No universal MOQ, sample, stock or lead-time commitment Quantity, sample status, supply route, destination, timing and written quotation terms

TONMIT INTERNAL TEST & MODEL EVIDENCE

Review the Internal Cold-Gel-Bottle Test Summary

The table below summarizes Tonmit internal duration results under three stated ambient conditions. It reports separate 2–8°C and 2–25°C windows; it is not a plot of raw logger readings and must not be transferred to another cup, bottle, preparation method or load without matching evidence.

INTERNAL PERFORMANCE SUMMARY · COLD-GEL BOTTLE CONFIGURATION

Duration by Ambient Test Condition

In the internal test summary supplied for this configuration, the configured cooling cup remained within each stated temperature window for the durations shown below.

Tonmit internal cold-gel-bottle duration summary
Ambient 2–8°C Window 2–25°C Window
30°C / 86°F 36 hours 48 hours
35°C / 95°F 30 hours 46 hours
40°C / 104°F 26 hours 44 hours

Range note: the 2–25°C column is a separate broader test window, not a universal insulin-storage instruction. Use the storage range stated on the selected medication label.

Evidence boundary: this on-page table is a summary, not the underlying validation record or raw temperature trace. Before commercial approval, match the report ID / revision, tested cup and bottle model, preparation, load, sensor position and environmental conditions to the quoted SKU.

PERFORMANCE RECORD CHECKLIST

Conditions to Match Before Applying the Result

  • Report ID / revision, test date and sample identification
  • Exact cup and cold-gel-bottle model / SKU
  • Bottle quantity, freezing time and preparation
  • Ambient temperature and humidity
  • Starting cup and internal-load temperature
  • Medication simulator or other internal load
  • Logger model, calibration status and accuracy
  • Sensor position and sampling interval
  • Opening events and total test duration
  • Acceptance window and recorded result
MODEL FILE INDEX Request before approval

Files to Match to the Quoted Model

Product specification
Model, dimensions, materials, internal clearance and included components
Packaging record
Unit pack, carton quantity, dimensions and packaging version
Instructions
Insert preconditioning, placement, use and handling where available
Label / artwork sample
Applicable market version or project-specific private-label proof
Performance record
Report ID, test date, exact cup-and-bottle model and test conditions where available
DOCUMENT IDENTITY Match before use

Confirm What Every File Actually Covers

For each supplied file, verify the legal manufacturer, exact model reference, document number, revision or validity date and applicable market. Evidence for one model or manufacturer should not be applied to another.

Legal manufacturer Exact model / SKU Document ID / revision Applicable market

The public page summarizes the review framework. Model-specific file references should be matched to the quotation before they are relied upon for procurement.

Request Model Specification & File Index

ADJACENT PRODUCT COMPARISON

Cooling Cup or Hard-Shell Travel Case?

Use the cooling cup when a compact insulated cup-and-insert system matches the requirement. Review the hard-shell case when organized multi-item storage and reusable flat cooling packs are more appropriate.

CURRENT PRODUCT FAMILY

Stainless-Steel Cooling Cup

  • Compact rigid insulated cup construction
  • Cold-gel bottle cooling configuration
  • Medication fit confirmed by internal clearance
  • Configuration-specific preparation and test evidence
Review cooling-cup controls
ADJACENT PRODUCT FAMILY

Hard-Shell Travel Case

  • Organized compartments and retainers
  • Reusable flat cooling-pack configurations
  • Multiple pens, cartridges or related supplies by model
  • Temperature-display option on selected configurations
Review travel-case models

RESPONSIBILITY BOUNDARY

Define the Inputs Before Commercial Approval

Tonmit can coordinate available model, packaging and document information. The buyer remains responsible for defining intended use, medication-specific storage requirements, destination-market requirements and final purchase approval.

Buyer Defines

  • Intended medication container and quantity
  • Required storage range and transport scenario
  • Destination market and labeling needs
  • Quantity, packaging and document requirements

Tonmit Confirms

  • Available cup model and internal clearance
  • Cold-gel-bottle model, preparation and included components
  • Packaging, quotation and supply route
  • Available model-specific files and evidence status

COOLING CUP SKU REVIEW

Request an Exact-Model Cooling Cup Review

Send the intended medication format, required storage range, quantity, destination, packaging and document needs. Tonmit will review available models and identify the configuration and evidence that must be confirmed before quotation.

Submit Cooling Cup Requirements